Calibration block No.1(V1)
Specifications:
EN12223
Calibration Function:
Calibration of shear and compression wave probes. Checking beam angle, emergent point and resolution. Calibration of time base and gain settings.
*We can provide V1 calibration block based on EN12223, BS2704, ASTM E164 and ISO 2400.
Calibration Block No.2 (V2)
Specifications:
EN27963
Calibration Function:
Small calibration block for on-site checking of miniature shear wave probe index, time base, beam angle and gain, engraved reference mark scales from 35 to 75 degrees.
*We can provide V2 calibration block based on EN27963, BS2704 and ISO 7963.
Phased Array Test Block Type A
Specifications:
ASME Code Cases 2541, 2557, 2558
Calibration Functions:
The Phased Array “Type A” Calibration Block is used during the initial setup and calibration of a phased array ultrasonic unit.
It can be used to perform tasks such as beam angle verification, calibration for wedge delay, sensitivity calibration, performing DAC/TCG for thickness up to 50 mm, and crack sizing.
Phased Array Test Block Type B
Specifications:
ASME Code Cases 2541, 2557, 2558
Calibration Functions:
The Phased Array “Type B” Calibration Block is used as baseline block to determine long-term instrument performance changes, generate DAC curves,
and evaluate linear/ angular resolution, focusing ability and beam steering capability.
Miniature Angle Beam (ROMPAS) Calibration Block
Specifications:
ASTM E164
Calibration Function:
Straight Beam: distance angle beam, index point, sound path angle (30°-70°).
DSC Distance/ Sensitivity Calibration Block
Specifications:
ASTM E164, AWS D1.1/D1.1M
Calibration Function:
Straight Beam: distance, amplitude. Angle Beam: index point, sound path angle (45°-70°),distance, sensitivity.
DC Distance Calibration Block
Specifications:
ASTM E164,AWS D1.1/D1.1M
Calibration Function:
Straight Beam: distance, amplitude. Angle Beam: index point, distance.
SC Sensitivity Calibration Block
Specifications:
ASTM E164, AWS D1.1/D1.1M
Calibration Function:
Angle Beam: sound path angle (45°, 60°, 75°), sensitivity.
DS Distance/ Sensitivity Calibration Block
Specifications:
AWS D1.1/D1.1M
Calibration Function:
Straight Beam: distance, horizontal linearity, sensitivity.
RC (AWS) Resolution Calibration Block
Specifications:
AWS D1.1/D1.1M
Calibration Function:
Angle Beam: resolution (45°, 60°, 70°).
IOW Beam Profile Block
Specifications:
API RP 2X
Calibration Function:
Angle Beam: beam profile (45°, 60°, 70°), probe angle.
ASME Basic Calibration Blocks
Specifications:
ASME BPVC-V (2010)
Calibration Function:
Used for establishment of primary reference responses for UT examination of welds.